Maintenance work on the carrier
7.14 Hydraulic system
13.02.2018
Maintenance manual 3 302 719 en 7 - 83
GMK6300L-1
After parts have been changed
• Bleed the carrier's hydraulic system; à Bleeding the hydraulic system,
p. 7 - 94.
If damage cannot be rectified immediately or further damage is likely
• Notify Manitowoc Crane Care or an authorised GROVE dealer or your repair
crew.
7.14.4 Cleaning the magnetic rods
Spare parts and
tools
– Receptacle, approx. 5 ltr (1.5 gal);
à p. 2 - 4.
Prerequisites – The truck crane must be standing on a level surface.
– The engine must be switched off and secured against unauthorised use;
à p. 2 - 3.
– During the first 100 operating hours: Clean the magnetic rods weekly.
s
G
Risk of accidents from hydraulic oil spraying out.
Never tighten any leaking connections when the system is under pressure.
Change pipes and hose lines only when the system is depressurised.
O
Risk of environmental damage due to leaking consumables.
Immediately repair or have leakages in the hydraulic system repaired to
ensure that no hydraulic oil escapes, seeps into the ground or reaches
waterways when the crane is being used.
M 3
Designation Quantity GROVE part no.
Filter 2 03329152
Packing set 2 03135778

Table of Contents

Other manuals for Manitowoc Grove GMK6300L-1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GMK6300L-1 and is the answer not in the manual?

Manitowoc Grove GMK6300L-1 Specifications

General IconGeneral
BrandManitowoc
ModelGrove GMK6300L-1
CategoryConstruction Equipment
LanguageEnglish

Related product manuals