Maintenance work on the superstructure
8.9 Hydraulic system
13.02.2018
Maintenance manual 3 302 719 en 8 - 71
GMK6300L-1
8.9.7 Pressure accumulator – checking the gas pressure
The superstructure is equipped with pressure
accumulators.
The filling pressure at 20 °C (68 °F) is:
• Have the filling pressure checked and if
necessary corrected by
Manitowoc Crane
Care
or an authorised GROVE dealer.
8.9.8 Taking oil samples
The oil sample from the superstructure hydraulic system is taken in a way
similar to that for the carrier hydraulic system.
Information for taking samples with the hose and for the laboratory
analys
is;
à Taking oil samples, p. 7 - 86.
Prerequisites – The engine must be switched off and secured against unauthorised use;
à p. 2 - 3.
Select the
sampling location
To determine the u
sability of the oil, you must take a sample from the
hydraulic system. To do that you must connect the hose with the connecting
piece to a gauge port.
s
M 12
G
Risk of accidents due to incorrect inspection.
The gas pressure test must be carried out only by an authorised official
inspector of pressure tanks or
under his/her supervision or instructions.
1 Pressure accumulator 20 bar (290 psi)
2 Pressure accumulator 180 bar (2610 psi)
M 12

Table of Contents

Other manuals for Manitowoc Grove GMK6300L-1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GMK6300L-1 and is the answer not in the manual?

Manitowoc Grove GMK6300L-1 Specifications

General IconGeneral
BrandManitowoc
ModelGrove GMK6300L-1
CategoryConstruction Equipment
LanguageEnglish

Related product manuals