Maintenance work on the superstructure
8.4 Fuel system
13.02.2018
Maintenance manual 3 302 719 en 8 - 29
GMK6300L-1
8.4.2 Replacing fuel filter 1
Optional Note the option; à p. 8 - 28.
Spare parts and
tool
s
– Receptacle, approx. 5 ltr (1.5 gal);
à p. 2 - 4.
Prerequisites – The truck crane must be level.
– The engine must be switched off and secured against unauthorised use;
à p. 2 - 3.
– If the fuel is dirty: Reduce the maintenance interval.
Changing
• Place a receptacle underneath the filter.
• Close the valve – lever (3) at right angles
to the line.
• Open the screw (1) and the valve (2)
and drain the consumable.
s
M 3
Designation Quantity GROVE part no.
Filter cartridge 1 04181165
Filter element 1 04181166
O
Risk of environmental damage due to leaking consumables.
Always let consumables drain into suitable recep
tacles. Wipe up any
consumables that escape.
Store/dispose of consumables and any soaked equipment properly.
Ask about the applicable regulations.

Table of Contents

Other manuals for Manitowoc Grove GMK6300L-1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GMK6300L-1 and is the answer not in the manual?

Manitowoc Grove GMK6300L-1 Specifications

General IconGeneral
BrandManitowoc
ModelGrove GMK6300L-1
CategoryConstruction Equipment
LanguageEnglish

Related product manuals