Maintenance work on the superstructure
8.5 Exhaust system with exhaust emission control
13.02.2018
Maintenance manual 3 302 719 en 8 - 37
GMK6300L-1
Filling up • Find out about filling up in the operating manual and note the warnings;
à Manual de instrucciones.
• Open the cover (1).
• Fill the AdBlue tank via the filler neck (2)
and close it using the cap.
• Close the cover (1).
• Check the filling level on the display in
the crane cab;
à p. 8 - 36.
8.5.3 Check the exhaust system for external damage
Spare parts
and tools
Prerequisites – The engine must be switched off and secured against unauthorised use;
à p. 2 - 3.
– The engine and the exhaust system must be cool.
s
G
Danger of scalding due to ammonia vapours.
Ammonia vapour can escape if the AdBlue tank is opened when the outside
temperature is high. Am
monia vapours can irritate mucous membranes,
skin and eyes.
Ensure that there is adequate fresh air supply and do not breathe in the
escaping ammonia vapours.
M 1
Designation Quantity GROVE part no.
Exhaust silencer with SCR catalytic
converter
(
SCR = Selective Cataly
tic Reduction)
1
03293335

Table of Contents

Other manuals for Manitowoc Grove GMK6300L-1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GMK6300L-1 and is the answer not in the manual?

Manitowoc Grove GMK6300L-1 Specifications

General IconGeneral
BrandManitowoc
ModelGrove GMK6300L-1
CategoryConstruction Equipment
LanguageEnglish

Related product manuals