Running-in regulations
13.02.2018
Maintenance manual 3 302 719 en 4 - 1
GMK6300L-1
4 Running-in regulations
There are regulations about running in individual parts which must
be followed, after:
– First commissioning or
– Replacement of a part or
– General overhaul.
This is why you must carry out additional main
tenance work on the carrier
and superstructure after specific periods of time have expired:
s
Operating
hours
(oper. hrs.)
Driven km
(mi)
Additional maintenance work on the
CARRIER
after 50 (30)
Tighten the wheel nuts;
à Special torques, p. 10 - 2.
after 150 (95) Tighten the wheel nuts;
à Special torques, p. 10 - 2.
after 50 Tighten the clips on the coolant hoses;
à Special torques, p. 10 - 2.
after 100 Lubricate the outrigger beams;
à Lubricating the outrigger beams, p. 7 - 124.
during the
first 100
Check the hydraulic oil filter every week,
and change it if necessary;
à Cleaning the magnetic rods, p. 7 - 83,
à Changing the hydraulic oil filter, p. 7 - 95.
after 100 after 1000
(650)
Change the drive oil;
à p. 7 - 46 for the transfer case,
à p. 7 - 52 for the axle centre drives,
à p. 7 - 56 for the final drives.
after 250 after 2500
( 1550)
Change the engine oil;
à Engine manufacturer’s documentation.