Maintenance work on the superstructure
8.14 Hook blocks
13.02.2018
Maintenance manual 3 302 719 en 8 - 109
GMK6300L-1
8.14 Hook blocks
8.14.1 Checking the sheaves
• Check the sheaves in the hook blocks for damage, wear, mobility and
extreme soiling.
Have damaged, worn, stiff or extremely soiled sheaves replaced by
Manitowoc Crane Care or an authorised GROVE dealer or your repair crew.
8.14.2 Lubricating
• Comply also with the à Running-in regulations, p. 4 - 1.
Grease, spare
parts, tools
– Grease gun from the tool set.
Prerequisites – The hook block has been reeved at least twice;
à Manual de instrucciones.
Lubricating
On the hook blocks supplied, the sheaves, crossheads and load hooks of
the axial bearings are greased.
H
The sheaves on the hook block often have no grease nipple and are
maintenance-free.
• Check all hook blocks for grease nipples. Hook blocks with grease nipples
must be serviced, hook blocks without grease nipples are maintenance-free.
s
M 3
M 12
Lubricating
grease
Designation
according to
DIN 51502
Specification
Classification
GROVE part no.
Grease KP - 1K - 50 DIN 51825 03233369

Table of Contents

Other manuals for Manitowoc Grove GMK6300L-1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GMK6300L-1 and is the answer not in the manual?

Manitowoc Grove GMK6300L-1 Specifications

General IconGeneral
BrandManitowoc
ModelGrove GMK6300L-1
CategoryConstruction Equipment
LanguageEnglish

Related product manuals