Maintenance work on the carrier
7.3 Engine
7 - 14 3 302 719 en Maintenance manual
GMK6300L-1
13.02.2018
7.3.3 Checking the air filter
If the symbol is displayed on the instrument panel in the driver's cab, the air
filter must be changed.
If the symbol is displayed in the
crane cab on
the ECOS display
(Warning
submenu), the air filter must be changed.
Spare parts
and t
ools
Prerequisites – The engine must be switched off and secured against unauthorised use;
à p. 2 - 3.
Replacing the
air filter
• Undo all the clamps (1) and remove the
cover (2).
• Change the main filter (3) and the back-up
filter (4).
• Replace the cover and secure it with all
the clamps.
D
Designation Quantity GROVE part no.
Main filter 1 04163882
Back-up filter 1 04163883