3-24
8
Repeat the procedures in the Step 6 and 7 to set other
commands.
• Perform the same operations as in Steps 6 and 7 to set other items.
9
Press the key.
10
Press the key several times to end the setting.
Setting the SHEET SENSOR
The sheet sensor detects whether there is a sheet or not, and the sheet length.
There are two sheet sensors on the platen.
In the following cases, set the sheet sensor to “OFF”.
• When a special sheet that cannot be detected by the sensor
• When the sensor may respond wrongly because there is a light just above this device
• Even if you set the sheet, [NO SHEET] is displayed on the screen
1
Press the key in LOCAL mode.
2
Press to select [SET UP].
3
Press the key.
4
Press to select [SHEET sensor].
• The set value is retained even when the power is turned "OFF".
• When the half cut is set to ON, even if the ZF command is set in the host, it becomes invalid.
• When you set the sheet sensor to “OFF”, be sure to set the cutting area. By setting this, you can
prevent the device from cutting outside sheet or from cutting continuously even after the device
reaches the sheet end.
• The set value is retained even when the power is turned "OFF".