9.
9 - 16
MAINTENANCE FUNCTION
9.8 System Display
The following items can be checked by connecting a peripheral device capable of GPP
functions to the QnACPU:
(1) The following information relating to the modules actually mounted on the base unit:
(a) Type
(b) No. of Occupied Points
(c) Head X/Y number
(2) The following module information set in the parameters:
(a) Type
(b) No. of Occupied Points
(c) Type Name
(3) The following information relating to the CPU module:
(a) Status of the RUN/STOP key switch
(b) Status of the system setting switches
(c) LED statuses
These items can be checked using the detail HELP display and CPU module panel items
in the display menu of the GPP function PLC diagnositics mode.