12-5
12 Pulse Outputs
CP2E CPU Unit Software User’s Manual(W614)
12-1 Overview
12
12-1-2 Flow of Operation
To perform an origin search or to use a Limit Input Signal as an input to a function other than origin
search, set the parameters on the Pulse Output 0 to 3 Tab Pages in the PLC Setup.
Pulse Output 0 to 3 Tab Page
Note The power supply must be restarted after the PLC Setup is transferred in order to enable the pulse output
settings.
Refer to 12-6 Defining Origin Position for origin search settings in the PLC Setup.
PLC Setup
Item Setting Description
Base
Settings
Undefined Origin Hold When a Limit Input Signal is input, the pulse output is
stopped and the previous status is held.
Undefined When a Limit Input Signal is input, the pulse output is
stopped and origin becomes undefined.
Limit Input Signal
Operation
Search Only The CW/CCW Limit Input Signal is used for origin
searches only.
Always The CW/CCW Limit Input Signal is used by functions
other than origin search.
Limit Input Signal NC Select when using NC contact (b contact) for the Limit
Input Signal.
NO Select when using NO contact (a contact) for the Limit
Input Signal.
Search/Return Ini-
tial Speed
Set the motor’s starting speed when performing an origin search. Specified in
pulses per second (pps).