Servicing the ZS4-4 Controller
1. Install additional 4x4 SAS-2 HBAs in slot 9, then slot 3.
2. Install InfiniBand CX3 HCAs into the first available client-option slot starting with slot 11,
then slot 8, slot 5, slot 1, slot 10, slot 3, slot 9.
3. Install 16Gb FC HBAs into the first available client-option slot starting with slot 11, then
slot 8, slot 5, slot 1, slot 10, slot 3, slot 9.
4. Install 10Gb Ethernet Optical NICs into the first available client-option slot starting with
slot 11, then slot 8, slot 5, slot 1, slot 10, slot 3, slot 9.
5. Install 10Gb Ethernet Copper NICs into the first available client-option slot starting with
slot 11, then slot 8, slot 5, slot 1, slot 10, slot 3, slot 9.
ZS4-4 PCIe Base and Optional Configurations
The following table describes the PCIe base and optional slot assignments for ZS4-4 standalone
and cluster configurations. PCIe slot numbering begins with slot 1.
See the legend for a description of the interconnect types and option codes shown in the Type
column.
Slot Description Max Type Note
1 2-port InfiniBand CX3 HCA 4 A Optional recommended front-
end
1 2-port 10Gb Ethernet Optical
NIC
4 C Optional recommended front-
end
1 2-port 10Gb Ethernet Copper
NIC
4 D Optional recommended front-
end
1 16GB Dual Universal FC HBA 4 B Optional FC target or initiator
(Backup)
2 8-port SAS-2 Internal HBA 1 F Base configuration
3 4-port (4x4) SAS-2 External
HBA
4 E Optional back-end
3 2-port InfiniBand CX3 HCA 4 A Optional recommended front-
end
3 2-port 10Gb Ethernet Optical
NIC
4 C Optional recommended front-
end
3 2-port 10Gb Ethernet Copper
NIC
4 D Optional recommended front-
end
3 16GB Dual Universal FC HBA 4 B Optional FC target or initiator
(Backup)
4 Cluster Interface (second
generation)
1 G Base configuration
52 Oracle ZFS Storage Appliance Customer Service Manual • February 2016