Servicing the ZS3-4 Controller
13.
If you re-installed a PCIe card, connect the data cables to the PCIe card, routing
them through the cable management arm, if used.
14.
When the system has finished booting, log in and set the time using the steps
in the BUI Clock task. For more information, see “Setting Clock Synchronization
using the BUI” in Oracle ZFS Storage Appliance Administration Guide, Release
2013.1.5.0.
Servicing the ZS3-4 Controller
This section describes how to service the ZS3-4 controller.
ZS3-4 Controller Hardware Overview
This section describes the internal and external components of the Oracle ZFS Storage ZS3-4
controller.
ZS3-4 Base Configuration
The ZS3-4 controller can be configured as a single controller or two controllers to create a high-
availability cluster configuration. The following table describes the configuration options:
TABLE 17
ZS3-4 Controller Features
Mktg Part
Number
CPU Memory
Readzilla
SAS-2
Boot Drive
SAS-2
HBA SAS-2
Software
Version (min)
7105725 4x10-core,
2.40GHz
1TB (16GB
DIMMs)
Four 1.6TB Two 900GB 4X4-port 2013.1.0
Refer to the product site at https://www.oracle.com/storage/nas/index.html for the most
recent component specification.
ZS3-4 Front Panel
The ZS3-4 controller drive slots and front panel components are shown in the following figure.
76 Oracle ZFS Storage Appliance Customer Service Manual • February 2016