Mixed Signal Operation (Option R&S RTC-B1)
R&S
®
RTC1000
111User Manual 1335.7352.02 ─ 02
For logic channels, the logic value of the selected POD is measured at the cursor
position and shown in hexadecimal and decimal format.
9.4 Automatic Measurements for Logic Channels
If the logic channels active, you can use the automatic measurement functions to
determine several parameters (AUTO MEASURE key).
The following measurement types are available:
FREQUENCY
PERIOD
PULSE WIDTH +/–
DUTY CYCLE+/–
DELAY
PHASE
BURST WIDTH
COUNT PULSE +/–
COUNT (pos./neg.)
9.5 Using Logic Channels in Buses
You can use logic channels as input sources of various buses. Parallel buses are dedi-
cated for analysis of logic channels. Serial buses accept analog and digital channels as
input.
The general usage of buses is described in the following chapters:
Chapter 11.1, "Bus Configuration", on page 120
Chapter 11.2, "Bus Table: Decode Results", on page 122
9.5.1 Parallel / Parallel Clocked Bus
The R&S RTC1000 has a parallel and parallel bus analysis by default. No option is
required. You can analyze up to 7 lines (7 bit).
To select the parallel or parallel bus
1. Press the BUS key in the Vertical section.
2. In the short menu, select the bus: "B1" or "B2".
3. In the "BUS" menu, press the softkey "BUS TYPE"
4. Use the UNIVERSAL knob to select "PARALLEL" or "PARALLEL CLOCKED".
Using Logic Channels in Buses

Table of Contents

Other manuals for R&S RTC1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the R&S RTC1000 and is the answer not in the manual?

R&S RTC1000 Specifications

General IconGeneral
BrandR&S
ModelRTC1000
CategoryTest Equipment
LanguageEnglish

Related product manuals