13.4.3 Width (Pulse) Trigger
TRIGger:A:WIDTh:POLarity............................................................................................ 203
TRIGger:A:WIDTh:RANGe..............................................................................................203
TRIGger:A:WIDTh:WIDTh...............................................................................................203
TRIGger:A:WIDTh:DELTa...............................................................................................204
TRIGger:A:WIDTh:POLarity <Polarity>
Sets the polarity of the pulse trigger function.
Parameters:
<Polarity> POSitive | NEGative
POSitive
Positive going pulse, the width is defined from the rising to the
falling slopes.
NEGative
Negative going pulse, the width is defined from the falling to the
rising slopes.
*RST: POSitive
TRIGger:A:WIDTh:RANGe <RangeMode>
Defines how the measured pulse width is compared with the given limit(s) .
Parameters:
<RangeMode> WITHin | OUTSide | SHORter | LONGer
WITHin | OUTSide
Triggers on pulses inside or outside a range defined by time ±
delta. The time is specified with TRIGger:A:WIDTh:WIDTh,
the range around is defined with TRIGger:A:WIDTh:DELTa.
SHORter | LONGer
Triggers on pulses shorter or longer than a time set with
TRIGger:A:WIDTh:WIDTh.
*RST: LONGer
TRIGger:A:WIDTh:WIDTh <Time1>
For the ranges WITHin and OUTSide (defined using TRIGger:A:WIDTh:RANGe), the
<Time1> defines the center of a range which is defined by the limits ±<Delta> (set with
TRIGger:A:WIDTh:DELTa).
For the ranges SHORter and LONGer, the width defines the maximum and minimum
pulse width, respectively.
Parameters:
<Time1> Center value, maximum value or minimum value depending on
the defined range type.
Range: 1.6E-08 to 3.435974E+01
Trigger

Table of Contents

Other manuals for R&S RTC1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the R&S RTC1000 and is the answer not in the manual?

R&S RTC1000 Specifications

General IconGeneral
BrandR&S
ModelRTC1000
CategoryTest Equipment
LanguageEnglish

Related product manuals