Pick-off Pawls and Toner Density Sensor
• Do not turn the PCU upside down. This causes toner and developer to spill out.
1. PCU ( p.101)
2. Pawl [A]
• Pull down the pawl and release the bottom end.
3.
Toner density sensor [B] (
x 1)
• The toner density sensor is taped to the bottom of the PCU. Pry it off with a regular screwdriver
4. After reinstalling the
pick-off pawls or toner density sensor, adjust the image quality (
p.106 "After
Replacement or Adjustment").