SP4-XXX (Scanner)
4008* Sub-Scan Magnification (Scanner) [-0.9 to +0.9 / 0.0 / 0.1%/step]
4008 1
Adjusts the actual sub-scan direction scanning magnification. The higher the setting, the
lower the scanner motor speed.
4009* Main Scan Magnification (Scanner) [–0.9 to +0.9 / 0.0 / 0.1%/step]
4009 1
Adjusts the magnification along the main scan direction, for scanning.
The specification is 100 ± 1.0%
Main scan magnification is implemented in steps of 0.5. Accordingly, your input value
should be a multiple of 0.5 (–1.0, –0.5, 0, +0.5, or +1.0)
4010* Leading Edge Registration (Scanner) [–5.0 to +5.0 / 0.0 / 0.1 mm/step]
4010 1
Adjusts the leading edge registration for scanning in platen mode ( Copy Adjustments
Printing/Scanning).
(–): The image moves toward the leading edge.
(+): The image moves toward the trailing edge.
The specification is 2 ± 1.5 mm.
4011* Side-to-side Registration (Scanner) [–4.2 to +4.2 / 0.0 / 0.1 mm/step]
4011 1
Adjusts the side-to-side registration for scanning in platen mode ( Copy Adjustments
Printing/Scanning)
Increasing the value shifts the image to the right
The specification is 2 ± 1.5 mm.
4012*
Scan Erase Margin
Adjusts the scanning margin individually for each of the four edges. It is generally best to
adjust the scanning margin as little as possible, and use the printing margin for image
adjustments.