2.Installation
8
2. Installation
Installation Requirements
Environment
1. Temperature Range: 10°C to 32°C (50°F to 89.6°F)
2. Humidity Range: 15% to 80% RH
3. Ambient Illumination: Less than 2,000 lux (do not expose to direct sunlight)
4. Ventilation: 3 times/hr/person
5. Do not install the machine at locations over 2,000 m (6,562 ft.) above sea level.
6. Atmospheric pressure: more than 740 hPa.
Main Machine Installation
This machine is installed by the user.
Moving and Transporting the Machine
It is dangerous to handle the power cord plug with wet hands. Doing so could result in electric
shock.
Unplug the power cord from the wall outlet before you move the machine. While moving the
machine, take care that the power cord is not damaged under the machine. Failing to take
these precautions could result in fire or electric shock.