Bit Switches
D649 98 SM
Communication Switch 11 – Not used (do not change the settings.)
Communication Switch 12 (SP No. 1-104-019)
No Function Comments
0-7
Memory transmission: Interval
between dialing attempts to the
same destination
01 – FF (Hex) minutes
Communication Switch 13 – Not used (do not change the settings.)
Communication Switch 14 (SP No. 1-104-021)
No Function Comments
0
Inch-to-mm conversion during
transmission
0: Disabled, 1: Enabled
0: In immediate transmission, data
scanned in inch format are transmitted
without conversion.
In memory transmission, data stored in
the SAF memory in mm format are
transmitted without conversion.
Note: When storing the scanned data
into SAF memory, the fax unit always
converts the data into mm format.
1: The machine converts the scanned
data or stored data in the SAF memory
to the format which was specified in the
set-up protocol (DIS/NSF) before
transmission.
1-5 Not used Do not change the factory settings.