Main SP Tables-1
SM Appendix 3-21 D117/D118
Appendix:
SP Mode
Tables
1124
[CPM Down Setting]
Sets the temperature differential used to calculate CPM down for low and high
temperatures. Also, sets the interval for temperature checks for CPM down.
001
Low:Down Temp. *ENG [-50 to 0 / -20 / 1 deg/step]
002
Low:Up Temp. *ENG [-50 to 0 / -15 / 1 deg/step]
003
Low :1st CPM *ENG [10 to 100 / 80 / 1 %/step]
004
Low :2nd CPM *ENG [10 to 100 / 65 / 1 %/step]
005
Low :3rd CPM *ENG [10 to 100 / 50 / 1 %/step]
006
High:1st CPM :Plain1:BW:LT *ENG [10 to 100 /100 / 1%/step]
007
High:2nd CPM :Plain1:BW:LT *ENG [10 to 100 / 100 / 1%/step]
008
High:3rd CPM :Plain1:BW:LT *ENG [10 to 100 / 100 / 1%/step]
012
High:1st Temp.:Plain1:BW:LT *ENG [0 to 250 / 210 / 1deg/step]
013
High:2nd Temp.:Plain1:BW:LT *ENG [0 to 250 / 215 / 1deg/step]
014
High:3rd
Temp.:Plain1:BW:LT
*ENG [0 to 250 / 220 / 1deg/step]
015
High:1st Temp.:Plain1:BW:B5 *ENG [0 to 250 / 50 / 1deg/step]
016
High:2nd
Temp.:Plain1:BW:B5
*ENG [0 to 250 / 129 / 1deg/step]
017
High:3rd Temp.:Plain1:BW:B5 *ENG [0 to 250 / 142 / 1deg/step]
018
Judging Interval *ENG [1 to 250 / 10 / 1sec/step]
019
High:1st Temp.:Plain1:BW:A5 *ENG [0 to 250 / 50 / 1deg/step]
020
High:2nd
Temp.:Plain1:BW:A5
*ENG [0 to 250 / 144 / 1deg/step]
021
High:3rd Temp.:Plain1:BW:A5 *ENG [0 to 250 / 148 / 1deg/step]
022
High:1st Temp.:Plain1:BW:B6 *ENG [0 to 250 / 50 / 1deg/step]

Table of Contents

Other manuals for Ricoh GR-C1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ricoh GR-C1 and is the answer not in the manual?

Ricoh GR-C1 Specifications

General IconGeneral
BrandRicoh
ModelGR-C1
CategoryAll in One Printer
LanguageEnglish

Related product manuals