Main SP Tables-2
D117/D118 3-72 SM Appendix
028 Average Coverage:4:C *ENG [0.00 to 100.00 / 0.05 / 0.01%/step]
029 Average Coverage:4:M *ENG [0.00 to 100.00 / 0.05 / 0.01%/step]
030 Average Coverage:4:Y *ENG [0.00 to 100.00 / 0.05 / 0.01%/step]
031 Mode Counter:K *ENG [0 to 999 / - / 1page/step]
032 Mode Counter:CMY *ENG [0 to 999 / - / 1page/step]
033 Execution Interval: Setting:5 *ENG [0 to 999 / 20 1page/step]
034 High Coverage Threshold:5 *ENG [60.00 to 100.00 / 60.00 / 0.01%/step]
035 Application Time:5 *ENG [0 to 99 / 3 / 1sec/step]
2101
[Registration Correction]
These values are the parameters for the automatic line position adjustment
and are adjusted at the factory. However, you must input a value for
SP2101-001 after replacing the laser optics housing unit. The value should be
provided with the new laser optics housing unit.
001 Color Main Dot: Bk *ENG
[–512 to 511 / 0 / 1dot/step]
002 Color Main Dot: Ma *ENG
003 Color Main Dot: Cy *ENG
004 Color Main Dot: Ye *ENG
005 Color Sub Line: Bk *ENG
[–16384 to 16383 / 0 / 1line/step]
006 Color Sub Line: Ma *ENG
007 Color Sub Line: Cy *ENG
008 Color Sub Line: Ye *ENG
2102
[Magnification Adjustment]
These values are the parameters for the automatic line position adjustment
and are adjusted at the factory. These SPs must be input only when a new
laser unit is installed.