Main SP Tables-5
SM Appendix 3-315 D117/D118
Appendix:
SP Mode
Tables
5505
[Error Alarm]
Sets the error alarm level.
The error alarm counter counts "1" when any SC is detected. However, the
error alarm counter decreases by "1" when an SC is not detected during a set
number of copied sheets (for example, default 1500 sheets).
The error alarm occurs when the SC error alarm counter reaches "5".
001 Error Alarm *CTL [0 to 255 / 10 / 1hundred/step]
5507
[Supply Alarm]
Enables or disables the notifying a supply call via the @Remote.
001 Paper Supply Alarm *CTL
[0 or 1 / 0 / 1/step]
0: OFF, 1: ON
003 Toner Supply Alarm *CTL
[0 or 1 / 1 / 1/step]
0: OFF, 1: ON
080 Toner Call Timing *CTL
Changes the timing of the "Toner
Supply Call" via the @Remote, when
the following conditions occur.
[0 or 1 / 0 / 1/step]
0: At replacement
1: At near end
128 Interval :Others *CTL
[250 to 10000 / 1000 / 1page/step]
133 Interval :A4 *CTL
134 Interval :A5 *CTL
142 Interval :B5 *CTL
164 Interval :LG *CTL
166 Interval :LT *CTL
172 Interval :HLT *CTL

Table of Contents

Other manuals for Ricoh GR-C1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ricoh GR-C1 and is the answer not in the manual?

Ricoh GR-C1 Specifications

General IconGeneral
BrandRicoh
ModelGR-C1
CategoryAll in One Printer
LanguageEnglish

Related product manuals