SC Tables
D117/D118 6-4 SM
Class 1 Section SC Code Detailed section
7XX Peripherals
700 - Original handling
720 - Two-tray finisher
740 - Booklet finisher
8XX Overall System
800 - Error after ready condition
820 - Diagnostics error
860 - Hard disk
880 - Unique for a specific model
9XX Others
900 - Counter
920 - Memory
990 - Others
6.1.2 SC1XX: SCANNING
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
101 D
Exposure lamp error
The peak white level is less than 64/255 digits (8 bits) when scanning
the shading plate.
ï‚§ Exposure lamp defective
ï‚§ Lamp stabilizer defective
ï‚§ Exposure lamp connector defective
ï‚§ Standard white plate dirty
ï‚§ Scanner mirror or scanner lens out of position or dirty
1. Check and clean the scanner mirror(s) and scanner lens.
2. Check and clean the shading plate.
3. Replace the exposure lamp.
4. Replace the lamp stabilizer.
5. Replace the scanner mirror(s) or scanner lens.