Main SP Tables-5
D117/D118 3-316 SM Appendix
5508 [CC Call]
001 Jam Remains *CTL
Enables/disables initiating a call for
an unattended paper jam.
[0 or 1 / 1 / 1/step]
0: Disable, 1: Enable
002 Continuous Jams *CTL
Enables/disables initiating a call for
consecutive paper jams.
[0 or 1 / 1 / 1/step]
0: Disable, 1: Enable
003 Continuous Door Open *CTL
Enables/disables initiating a call when
the front door remains open.
[0 or 1 / 1 / 1/step]
0: Disable, 1: Enable
011
Jam Detection: Time
Length
*CTL
Sets the time a jam must remain
before it becomes an “unattended
paper jam”. This setting is enabled
only when SP5508-004 is set to "1".
[3 to 30 / 10 / 1min./step]
012
Jam Detection: Continuous
Count
*CTL
Sets the number of consecutive paper
jams required to initiate a call. This
setting is enabled only when
SP5508-004 is set to "1".
[2 to 10 / 5 / 1/step]
013 Door Open: Time Length *CTL
Sets the length of time the door
remains open before the machine
initiates a call.
This setting is enabled only when
SP5-508-004 is set to "1".
[3 to 30 / 10 / 1min./step]