Main SP Tables-1
D117/D118 3-58 SM Appendix
005
Temp.:Rotation Threshold
Value1
*ENG [-100 to 100 / -100 / 1deg/step]
Specifies the threshold temperature 1 for the warming up rotation in the low
temperature condition.
010
Time:Heat Storage Devision1 *ENG [0 to 1000 / 0 / 1sec/step]
Specifies the execution time 1 for the warming up in the low temperature
condition.
011
Time:Heat Storage Devision2 *ENG [0 to 1000 / 0 / 1sec/step]
Specifies the execution time 2 for the warming up in the low temperature
condition.
1157
[Overshoot Prevent Control]
-
001 Decision Time ENG [0 to 200 / 1 / 1sec/step]
002 Off Sleep Shift Time *ENG [0 to 200 / 60 / 1sec/step]
003 Decision Temp. *ENG [0 to 250 / 250 / 1deg/step]
1190 [Flicker Control]
001 Flicker Control *ENG [0 or 1 / 0 / 1/step]
1801
[MotorSpeedAdjust]
Adjusts the speeds of each motor.
001 transportM:Plain1/2 *ENG [-4.00 to 4.00 / 0.43 / 0.01%/step]
002 transportM:Thin *ENG [-4.00 to 4.00 / 0.43 / 0.01%/step]
003 transportM:M-Thick *ENG [-4.00 to 4.00 / 0.43 / 0.01%/step]
004 transportM:Thick1 *ENG [-4.00 to 4.00 / 0.43 / 0.01%/step]
005 transportM:Thick2 *ENG [-4.00 to 4.00 / 0.43 / 0.01%/step]

Table of Contents

Other manuals for Ricoh GR-C1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ricoh GR-C1 and is the answer not in the manual?

Ricoh GR-C1 Specifications

General IconGeneral
BrandRicoh
ModelGR-C1
CategoryAll in One Printer
LanguageEnglish

Related product manuals