Bit Switches
D649 108 SM
4-7
Modem types available for reception
The setting of these bits is used to inform the transmitting terminal of the available
modem type for the machine in receive mode.
If V.34 is not selected, V.8 protocol must be disabled manually.
Cross reference
V.8 protocol on/off - G3 switch 03, bit 2
Bit 7 Bit 6 Bit 5 Bit 4 Types
0 0 0 1 V.27ter
0 0 1 0 V.27ter, V.29
0 0 1 1 V.27ter, V.29, V.33
0 1 0 0 V.27ter, V.29, V.17/V.33
0 1 0 1 V.27ter, V.29, V.17/V33, V.34
Other settings - Not used
G3 Switch 07 (SP No. 1-105-008)
No Function Comments
0-1
PSTN cable equalizer
(tx mode: Internal)
Use a higher setting if there is signal loss
at higher frequencies because of the
length of wire between the modem and
the telephone exchange.
Use the dedicated transmission
parameters for specific receivers.
Also, try using the cable equalizer if one
or more of the following symptoms
occurs.
Communication error
Modem rate fallback occurs frequently.
 This setting is not effective in
V.34 communications.
Bit 1 Bit 0 Setting
0 0 None
0 1 Low
1 0 Medium
1 1 High

Table of Contents

Other manuals for Ricoh GR-C1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ricoh GR-C1 and is the answer not in the manual?

Ricoh GR-C1 Specifications

General IconGeneral
BrandRicoh
ModelGR-C1
CategoryAll in One Printer
LanguageEnglish

Related product manuals