Latest: B Color 1200 ENG
4645
[Scan Adjust Error]
Displays the error value of the scanning adjustment.
001 White level ENG
[0 to 65535 / - / 1/step]
002 Black level ENG
4647
[Scanner Hard Error]
Displays the result of the SBU connection check.
001 Power-ON ENG
[0 to 65535 / - / 1/step]
0: OK, Other: SBU connection check
failure
If the SBU connection check fails, SC144
occurs.
4654
[Black Level Adj. Display]
Displays the last correct adjustment value of the black level.
RE: Red Even signal, RO: Red Odd signal
001
Last Correct Value: R
Color 600
*ENG
Displays the black offset value for the
even red signal in the CCD circuit board
(color printing speed).
[0 to 255 / - / 1digit/step]
002
Last Correct Value: R
Color 1200
*ENG
Displays the black offset value for the
odd red signal in the CCD circuit board
(color printing speed).
[0 to 255 / - / 1digit/step]