TC35i AT Command Set
7.18 +++
s
m
obil
e
TC35i_ATC_V02.07 Page 165 of 439 1/30/04
Confidential / Released
7.18 +++ Switch from data mode to command mode
Syntax
Command Description
This command is only available during a data call. The +++ character sequence causes the TA to cancel the data
flow over the AT interface and switch to command mode. This allows you to enter AT commands while maintain-
ing the data connection to the remote device.
To prevent the +++ escape sequence from being misinterpreted as data, it must be preceded and followed by a
pause of at least 1000 ms. The +++ characters must be entered in quick succession, all within 1000 ms.
Note
• To return from command mode to data mode: Enter ATO.
Exec Command
+++
Response(s)
OK
PIN ASC0 MUX1 MUX2 MUX3
! % % % %
Reference(s)
V.25ter