TC35i AT Command Set
2.9 AT+CFUN
s
m
obil
e
TC35i_ATC_V02.07 Page 39 of 439 1/30/04
Confidential / Released
2.9 AT+CFUN Set phone functionality
This command serves to control the functionality level of the ME. It can be used to reset the ME, to choose one
of the SLEEP modes or to return to full functionality.
Intended for power saving, SLEEP mode reduces the functionality of the ME to a minimum and thus minimizes
the current consumption. SLEEP mode falls in two categories: NON-CYCLIC SLEEP mode
<fun>=0 and
CYCLIC SLEEP modes, selectable as
<fun>= 5, 6, 7 or 8.
NON-CYCLIC SLEEP mode permanently blocks the serial interface. The CYCLIC SLEEP mode, however, is a
dynamic process which alternatingly enables and disables the serial interface. The major benefit of all CYCLIC
SLEEP modes is that the serial interface remains accessible and that, in intermittent wake-up periods, characters
can be sent or received without terminating the selected mode. The best choice is using
<fun>=7 or 8, since in
these modes TC35i automatically resumes power saving, after you have sent or received a short message or
made a call.
<fun>=5 or 6 do not offer this feature to the same extent and are only supported for compatibility
with earlier releases. In all CYCLIC SLEEP modes, you can enter
<fun>=1 to permanently wake up TC35i and
take it back to full functionality. Please refer to section 2.9.1 for a summary of all SLEEP modes and the different
ways of waking up the module.
For CYCLIC SLEEP mode (
<fun>= 5, 6, 7 or 8) both the ME and the application must be configured to use hard-
ware flow control. This is necessary since the CTS signal is set/reset every time when the ME listens to a paging
message from the base station. This is the way how the module indicates to the application when the UART is
active. For detailed information on the timing of the CTS signal refer to [2]. The default setting of hardware flow
control is
AT\Q0 which must be altered to AT\Q3. For use after restart you are advised to add it to the user profile
saved with
AT&W.
Syntax
Test Command
AT+CFUN=?
Response(s)
+CFUN: (list of supported <fun>s) , (list of supported <rst>s)
OK
Read Command
AT+CFUN?
Response(s)
+CFUN: <fun>
OK
Write Command
AT+CFUN=[<fun>[, <rst>]]
Response(s)
OK
ERROR
+CME ERROR
PIN ASC0 MUX1 MUX2 MUX3
! % § § §