TC35i AT Command Set
11.2 AT+CMGC
s
m
obil
e
TC35i_ATC_V02.07 Page 279 of 439 1/30/04
Confidential / Released
11.2 AT+CMGC Send an SMS command
Syntax
Notes
• After invoking the commands AT+CMGW, AT+CMGS or AT+CMGC it is necessary to wait for the prompt ">"
before entering text or PDU. After the prompt a timer will be started to observe the input.
• At baudrates below 19200 it is recommended to use the line termination character only (refer to
ATS3, default
<CR>) before entering the text or PDU. Use of the line termination character followed by the response format-
ting character (refer to
ATS4, default <LF> can cause problems
Test Command
AT+CMGC=?
Response(s)
OK
Write Command
If text mode (see AT+CMGF=1)
AT+CMGC=<fo>, <ct> [, <pid>[, <mn>[, <da>[, <toda>]]]] <CR> Text can be entered <CTRL-Z>/<ESC>
Response(s)
+CMGC: <mr>[, <scts>]
If sending fails
ERROR
+CMS ERROR
Write Command
If PDU mode (see AT+CMGF=0)
AT+CMGC=<length> <CR> PDU can be entered <CTRL-Z>/<ESC>
Response(s)
+CMGC: <mr>[, <ackpdu>]
OK
If sending fails
ERROR
+CMS ERROR
PIN ASC0 MUX1 MUX2 MUX3
% % % % %
Reference(s)
GSM 07.05