TC35i AT Command Set
2.2 AT&V
s
m
obil
e
TC35i_ATC_V02.07 Page 29 of 439 1/30/04
Confidential / Released
2.2 AT&V Display current configuration
Syntax
Command Description
TA returns the current parameter setting. The configuration varies depending on whether or not PIN authentica-
tion has been done and whether or not Multiplex mode is enabled (see
AT+CMUX).
Parameter Description
[0] Profile number
Notes
• The value of \Q (flow control) is also determined by the AT+IFC command. In case the value set by AT+IFC
cannot be represented by a \Q equivalent, \Q255 will be displayed.
• The parameters of
AT^SMGO can only be displayed after the SMS data from the SIM have been read success-
fully for the first time. Reading starts after successful SIM authentication has been performed, and may take
up to 30 seconds depending on the SIM used. While the read process is in progress, an attempt to read the
parameter will result in empty values.
• The parameter of
AT+CSDH will only be displayed in SMS text mode, see AT+CMGF
2.2.1 AT&V responses
The following tables show four different kinds of responses depending on whether or not the PIN is entered and
whether or not the Multiplex mode is enabled (see
AT+CMUX).
Exec Command
AT&V[<value>]
Response(s)
ACTIVE PROFILE:
... (see section 2.2.1)
OK
PIN ASC0 MUX1 MUX2 MUX3
! % % § §
Reference(s)
V.25ter
<value>
(num)