TC35i AT Command Set
10.20 AT+FPHCTO
s
m
obil
e
TC35i_ATC_V02.07 Page 265 of 439 1/30/04
Confidential / Released
10.20 AT+FPHCTO DTE Phase C Response Timeout
Syntax
Command Description
The time-out value <tout> determines how long the DCE will wait for a command after reaching the end of data
when transmitting in Phase C. When time-out is reached, the DCE assumes that there are no more pages or
documents to send.
Parameter Description
Timeout
Value in 100ms units
0...30
(P)
...255
Note
• Used for Fax Class 2 only
Read Command
AT+FPHCTO?
Response(s)
<tout>
OK
Write Command
AT+FPHCTO=<tout>
Response(s)
OK
If error is related to ME functionality
ERROR
PIN ASC0 MUX1 MUX2 MUX3
! % % ! !
Reference(s)
EIA PN-2388
<tout>