EasyManuals Logo
Home>Siemens>Modem>TC35i Terminal

Siemens TC35i Terminal User Manual

Siemens TC35i Terminal
439 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #38 background imageLoading...
Page #38 background image
TC35i AT Command Set
2.8 ATZ
s
m
obil
e
TC35i_ATC_V02.07 Page 38 of 439 1/30/04
Confidential / Released
2.8 ATZ Set all current parameters to user defined profile
Syntax
Command Description
TA sets all current parameters to the user profile stored with AT&W. If a connection is in progress, it will be termi-
nated.
The user defined profile is stored to the non-volatile memory.
Parameter Description
[0] Reset to user profile
Notes
• First the profilewill be set to factory default (see AT&F). If there is a valid user profile (stored with AT&W), this
profile will be loaded afterwards.
• Any additional commands on the same command line may be ignored. A delay of 300 ms is required before
next command is sent, otherwise "OK" response may be corrupted.
Exec Command
ATZ[<value>]
Response(s)
OK
PIN ASC0 MUX1 MUX2 MUX3
! % % % %
Reference(s)
V.25ter
<value>
(num)