TC35i AT Command Set
10.2 AT+FBADLIN
s
m
obil
e
TC35i_ATC_V02.07 Page 246 of 439 1/30/04
Confidential / Released
10.2 AT+FBADLIN Bad Line Treshold
Syntax
Command Description
This command defines the Copy-Quality-OK-threshold. If <badlin> consecutive lines have pixel count errors
in normal resolution (98 dpi) mode, then the copy quality is unacceptable. If
<badlin> * 2 consecutive lines have
pixel count errors in fine resolution (196 dpi) mode, then the copy quality is unacceptable. "Copy Quality Not OK"
occurs if either the error percentage is too high or too many consecutive lines contain errors. A value of 0 implies
that error checking is not present or disabled.
Parameter Description
bad lines
0...10
(P)
...255
Note
• Used for Fax Class 2 only
Read Command
AT+FBADLIN?
Response(s)
<badlin>
OK
Write Command
AT+FBADLIN=<badlin>
Response(s)
OK
If error is related to ME functionality
ERROR
PIN ASC0 MUX1 MUX2 MUX3
! % % ! !
Reference(s)
EIA PN-2388
<badlin>
(num)