TC35i AT Command Set
7.21 AT+CRLP
s
m
obil
e
TC35i_ATC_V02.07 Page 170 of 439 1/30/04
Confidential / Released
Mobile window size (MS to IWF)
0...[10]...61
(&F)
Acknowledgement timer (T1 in 10 ms units)
48...[78]
(&F)
...255
Re-transmission attempts N2
1...[6]
(&F)
...255
0 RLP version number in integer format; when version indication is not present it
shall equal 0.
Notes
• RLP version 0: single-link basic version;
• RLP version 1: single-link extended version (e.g. extended by data compression);
• RLP version 2: multi-link version.
• Compression and multi-link are not supported.
<mws>
(num)(&W)(&V)
<T1>
(num)(&W)(&V)
<N2>
(num)(&W)(&V)
<verx>
(num)

Table of Contents