Manual R06-2016 61 / 172
ROTARY INDEXING TABLE CONTROLLER
EF2...B
INSTALLATION | 6.2 Power Module PM240-2; frame size FSA / FSB
6.2.4.1 Power mains connection 1 AC 200 V - 240 V / 0.37 kW
Cyclical switching of the supply voltage is not allowed. After each shutdown, wait five
minutes before switching it on again.
The plug connections are located on the bottom side of the power module.
Fig. 33: Power mains connection 1 AC 200 V - 240 V / 0.37 kW
Name
Power mains connection plug
Release lever
L1 Line phase L
N Line phase N
PE Protective ground
Class J UL safety fuses
Rated current 10 A
Screw terminals
Cross-section
Tightening torque
Stripping length
1.5 to 2.5 mm
2
0.5 mm
8.0 mm