Manual R06-2016 67 / 172
ROTARY INDEXING TABLE CONTROLLER
EF2...B
INSTALLATION | 6.3 Brake Relay
6.3 Brake Relay
6.3.1 Mounting the brake relay
The safe brake relay is mounted on the rear of the bottom shielding plate of the power module.
Fig. 39: Mounting the brake relay
1. Mount the brake relay (SBR) on the rear of the shielding plate.
2. Mount the shielding plate with brake relay on the power module.
Shielding plate assembly see chapter 6.2.2 „Mounting the shielding plate“ on page 58.
3. Insert the cable of the brake relay into the socket on the brake relay.
4. Remove the CPU module from the power module.
5. Insert the cable of the brake relay into the Safe-Brake terminal.
6. Route the cable of the brake relay through the channel in the power module to the Safe-Brake terminal.
7. Plug the CPU module onto the power module.
Frame size FSA
SBR
SBR
Frame size FSB