5 - 2 DS8178 Digital Scanner Product Reference Guide
Scanning Sequence Examples
In most cases, scanning one bar code sets the parameter value. For example, to set the beeper tone to high, scan
the High Frequency (beeper tone) bar code listed under Beeper Tone on page 5-9. The digital scanner issues a
fast warble beep and the LED turns green, signifying a successful parameter entry.
Other parameters, such as Serial Response Time-Out or Data Transmission Formats, require scanning several
bar codes. See these parameter descriptions for this procedure.
Errors While Scanning
Unless otherwise specified, to correct an error during a scanning sequence, just re-scan the correct parameter.
User Preferences Parameter Defaults
Table 5-1 lists defaults for user preferences parameters. To change the default values:
•
Scan the appropriate bar codes in this guide. These new values replace the standard default values in
memory. To recall the default parameter values, see Default Parameters on page 5-5.
•
Configure the digital scanner using the 123Scan
configuration program (see Chapter 17, 123Scan and
Software Tools).
NOTE See Appendix A, Standard Parameter Defaults for all user preferences, hosts, symbologies, and
miscellaneous default parameters.
Table 5-1 User Preferences Parameter Defaults
Parameter
Parameter
Number
1
SSI Number
2
Default
Page
Number
Set Default Parameter Restore Defaults
5-5
Parameter Bar Code Scanning 236 ECh Enable
5-6
Beep After Good Decode 56 38h Enable
5-6
Direct Decode Indicator 859 F2h 5Bh Disable
5-7
Beeper Volume 140 8Ch High
5-8
Beeper Tone 145 91h Medium
5-9
Beeper Duration 628 F1h 74h Medium
5-10
Suppress Power Up Beeps 721 F1h D1h Do Not Suppress
5-10
Decode Pager Motor 613 F1h 65h Enable
5-11
Decode Pager Motor Duration 626 F1h 72h 150 msec
5-11
1
Parameter number decimal values are used for programming via RSM commands.
2
SSI number hex values are used for programming via SSI commands.