1 689 988 238 2012-11-06| Robert Bosch GmbH
Program description | ACS 651/751 | 113
en
10. Press E.
The following “Information” screen is displayed.
i If the engine is not OK, select “No” and press E.
Execute the steps listed in chapter 6.13.8.
11. If the engine is OK, press E.
The following screen is displayed.
12. If the A/C system is OK, press E. Execute the
steps listed in chapter 6.13.6.
i If the A/C system is not OK, select “No” and
press E. Execute the steps listed in chapter
6.13.7.
6.13.6 Executing recovery when the engine and the
A/C system are OK
i After executing step 12 of chapter 6.13.5, the follow-
ing screen is displayed.
1. Follow the instructions on the screen and press E.
The following screen is displayed.
2. Follow the instruction on the screen and press E.
The recovery phase is initiated.
i After the oil drain is completed, the following
screen is displayed.
i The recovery phase continues till the absolute pres-
sure is 600 mbar. When the recovery is completed,
it is possible to select and execute the other service
phases.