c) Connect the supercap cable from the RAID controller card to the connector on the supercap cable.
Step 4
Replace the top cover to the server.
Step 5
Replace the server in the rack, replace cables, and then fully power on the server by pressing the Power button.
Figure 46: Supercap Bracket on Air Baffle
Securing tab2Supercap bracket on removeable air baffle1
Replacing a SATA Interposer Card (8-Drive Server Only)
The only version of this server that supports controlling front-loading drives with embedded SATA RAID
is the SFF, 8-drives version (UCSC-C240-M5S).
Note
For software-based storage control that uses the server's embedded SATA controller to control front-loading
drives, the server requires a SATA interposer card that plugs into a dedicated socket on the motherboard (the
same socket used for SAS storage controllers).
Cisco UCS C240 M5 Server Installation and Service Guide
105
Maintaining the Server
Replacing a SATA Interposer Card (8-Drive Server Only)