RAID Controller Migration
The SFF, 8-drives version of the server (UCSC-C240-M5S) can use the software-based, embedded SATA
RAID controller to control front-loading SATA drives.
For SFF, 8-drives version only (UCSC-C240-M5S): Do not mix controller types in the server. Do not use
the embedded SATA controller and a hardware-based RAID controller card to control front-loading drives
at the same time. This combination is not supported and could result in data loss.
Note
See the table below for which data migrations are allowed and a summary of migration steps.
Migrate to Software RAID
Allowed?
Migrate to Hardware RAID
Allowed?
Starting RAID Controller
Allowed
1
Install SATA interposer card.
2
Connect SATA cables.
3
Enable embedded RAID in
BIOS.
Allowed
1
Install RAID card.
2
Connect SAS cables.
None (no drives).
Embedded RAID is disabled in the
BIOS.
-Data migration from
software RAID to
hardware RAID is not
supported and could
result in data loss.
Caution
Allowed only before there is data
on the drives; data migration is not
supported.
1
Disable embedded RAID in the
BIOS.
2
Install RAID card.
3
Install SAS cables.
Embedded software RAID.
Embedded RAID is enabled in the
BIOS.
Not allowed.-Hardware RAID.
Embedded RAID is disabled in the
BIOS.
Storage Controller Cable Connectors and Backplanes
This section describes cabling for the storage controllers and backplanes. The SAS/SATA cables are
factory-installed and are used for all supported internal controllers.
Cisco UCS C240 M5 Server Installation and Service Guide
133
Storage Controller Considerations
RAID Controller Migration