108 Dover Fueling Solutions W2940305 Rev 07 8/2019
Function Sub-Function Descri
tion
Measurement mode
1=Liters
2=Gallons
3=Im
erial
allons
.01 Pulser reverse
ulse h
steresis, 1-64
.03 Reverse
ulse limit
after h
steresis
on an idle/unused
ulser, 1-255
Meter t
e
1=WIP
2=PPM w/ LC meter
3=PPM w/ E85 mete
4=xFlo, 5=LC & iMeter combo
.00 Max. # of
ulse errors on an in-use
ulser
in a transaction
, 1-99
.01 Max. # of
ulse errors on an idle/unused
ulser, 1-99
.02 Max. # of dis
la
errors/fillin
, 0-99, 0 = disabled
.03 Sto
for “no flow” time limit, 0-1000 seconds
.04 Max. # of consecutive no flow events w/o error, 0-10, 0 = disabled
.05 Max. # of flow lost events w/o error, 0-10, 0 = disabled
.06 Max. # of unfinished fillin
s, 0-10, 0 = disabled
.07 Max. $ fillin
amount/fillin
, 1-6 di
its
.08 Max. volume amount/fillin
, 1-6 di
its
.09 Sto
for “flow lost” time limit ,0-1000 seconds
.10
Suppressed volume @ start of filling, 1-9 cl.
.11
Max. volume for selection of new product, 1-9 cl.
.12
Suppress overflow of preset limit, 0-99 cl.
.13
Preset/prepay slow down volume delta, 5-399 cl.
.14
Forward pulse limit on idle/unused WIP, 1-99 cl.
Liters pulse output resolution
0=Disabled
1=1 pulse per unit
2=10 pulses per uni
3=100 pulses per unit
4=250 pulses per unit
Calibration Test Container Volume –Liters (UHC only)
20 – 1000 Liters
.20
Suppressed volume @ start of filling, 1-99 (units of .001 gals.)
.21
Max. volume for selection of new product, 1-99 (units of .001 gals.)
.22
Suppress overflow of preset limit, 0-99 (units of .001 gals.)
.23
Preset/prepay slow down volume delta, 2-999 (units of .001 gals.)
.24
Forward pulse limit on idle/unused pulser, 1-999 (units of .001 gals.)
Gallons pulse output resolution
0=Disabled
1=1 pulse per unit
2=10 pulses per uni
3=100 pulses per unit
4=250 pulses per unit
5=500 pulses per unit
6=1000 pulses per uni
Calibration Test Container Volume – Gallons (UHC only)
5 – 250 Gallons
Denomination ratio between money display and unit price displa
1 =1/1
2 =10/1
3 =100/1
4 =1/10
5 =1/100
6 =1/1000
Count by ones or fives in least significant digit of money displa
1=Ones
2=Fives
.02
Volume digits to the right of the decimal point used in the amount
.03
Money preset configuration
Default price mode
1=Credit
2=Cash
.04
F22
F16 .00
.04
.15
.16
.25
.26
F19
F17
.00
.01
G.10 Metrological Configuration Parameter Definitions