set tftp timeout
2-42 Basic Configuration
Example
Thisexampleshowstheoutputofthiscommand.
D2(ro)->show tftp settings
TFTP packet timeout (seconds): 2
TFTP max retry: 5
set tftp timeout
UsethiscommandtoconfigurehowlongTFTPwillwaitforareplyofeitheranacknowledgement
packetoradatapacketduringadatatransfer.
Syntax
set tftp timeout seconds
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
Thisexamplesetsthetimeoutperiodto4seconds.
D2(rw)->set tftp timeout 4
clear tftp timeout
UsethiscommandtoresettheTFTPtimeoutvaluetothedefaultvalueof2seconds.
Syntax
clear tftp timeout
Parameters
None.
Defaults
None.
Mode
Switchcommand,readwrite.
seconds Specifiesthenumberofsecondstowaitforareply.Thevalidrangeis
from1to30seconds.Defaultvalueis2seconds.