03-l 2
Auxiliary Systems
03-I 2
DISTRIBUTORLESS IGNITION SYSTEM REMOVAL AND INSTALLATION (Continued)
Ignition System
Crankshaft Position Sensor
Removal
1. Disconnect battery ground cable (14301).
2. Drain cooling system.
3. Using flex handle, rotate drive belt tensioner
(6B209) and remove drive belt (8620).
4. Disconnect generator connectors. Remove three
bolts and generator (10300).
5. Remove lower radiator hose (8B273) and heater
water hose (18C266) from water pump inlet tube
(8290).
6. Remove two bolts and water pump inlet tube
(8290). Remove O-ring from water pump inlet
tube (8290).
PPDB5769-A
Item
1
2
3
4
5
6
7
A
B
Part
Number
8620
68209
N60676-S2
10153
8290
N606068-S
10300
-
-
Description
Drive Belt
Drive Belt Tensioner
Screw, M6-1 x 22.5
Generator Mounting Bracket
Water Pump Inlet Tube
Bolt, MIO-1.5 x 80
Generator
Tighten to 9-12 Nom
(84-l 08 Lb-In)
Tighten to 41-54 Nom
(30-40 Lb-Ft)
7. Disconnect crankshaft position sensor connector.
GENERATOR
BRACKET
10153
CONNECTOR
I
(PART OF 12A581)
SENSOR
60315
B5770-A