214
Chapter 8 Configuring Hardware and Utilities
8.1.10 IPMI Submenu
This submenu appears when selecting "IPMI" from the advanced menu.
Use this submenu to configure server management settings.
Power-Off Source
Software • Disabled
• Enabled (Initial value)
Sets whether or not to enable the power to be
turned off using a program or the operating
system.
Power Button • Disabled
• Enabled (Initial value)
Sets whether or not to allow the use of the
power switch for turning the power off, when
the ACPI function is disabled.
Power Failure Recovery • Always On
•Always Off
• Previous State
(Initial value)
Sets whether to turn the power on or off after
a temporary main power outage due to power
interruption, etc.
Note:
For UPS scheduled operation, set to
[Always On]. Otherwise, the power
may not be turned on at the specified
time.
table: Items on the IPMI Submenu
Item Setting Description
SEL Load Displays the usage of event log space as a percentage.
Clear System Event Log • Disabled
(Initial value)
• Enabled
Sets whether or not to clear the event log.
table: Items on the Power On/Off Submenu
Item Setting Description
Item Specific Help
Select Item
Select Menu
Change Values
Select Sub-Menu
-/+
Enter
F1
Esc
Help
Exit
F9
F7
Setup Defaults
Previous Values
Advanced Security Server ExitMain
Configure serial port
using options:
[Disabled]
No configuration
[Enabled]
User configuration
[Auto]
BIOS or OS chooses
configuration
IPMI
xx%
[Disabled]
[Overwrite]
[Enabled]
SEL Load
Clear System Event Log
Event Log Full Mode
BMC Time Sync
System Event Log
SDRR Browser
LAN Setting