Stress Echo
7-8 Vivid S70 / S60 – User Manual
BC092760-1EN
01
Moving an acquired image
An Image can be moved from one cell to another during
acquisition. There are two ways to move images.
Procedure 1
1. in the Protocol screen, press Move image.
2. Trackball to the image to move (source cell).
3. Press Select.
4. Trackball to the destination cell.
5. Press Select.
The image is moved from the source cell to the destination
cell.
Procedure 2
1. In the Protocol screen, trackball to the cell containing the
image to move (source cell).
2. Press and hold down Select.
3. With the Select key still depressed, trackball to the
destination cell.
4. Release the Select key.
The image is moved from the source cell to the destination
cell.
If the destination cell contains an image, the images from the
source and destination cells will be exchanged when moving an
acquired image.
Timers
Two timers can be displayed in the Stress mode acquisition
screen, beside the template matrix.
• T1 displays the elapsed time from the start of the stress
examination.
• T2 starts when entering live scanning on the second stress
level
Press Protocol T2 on the Touch panel to stop/start the T2 timer.
Timers restart always at zero.
The display of T1 and T2 is user-configurable (see page 7-26).