Checking the valve clearance
Front head
- Remove the plastic parts in order to free the head
cover access.
- Undo the six fixing screws and remove the tappet
cover together with the gasket.
- Check the valve clearance, and if necessary, re-
store the correct clearance.
Characteristic
Valve clearance
Inlet: 0.15 mm
Outlet: 0.15 mm
See also
Side fairings
Air filter
Rear head
- Remove the plastic parts in order to free the head
cover access.
- Undo the six fixing screws and remove the tappet
cover together with the gasket.
- Check the valve clearance, and if necessary, re-
store the correct clearance.
Characteristic
Valve clearance
Inlet: 0.15 mm
Outlet: 0.15 mm
See also
Helmet bay
- According to the procedure described in the «Engine Chapter» fit the tappet cover.
See also
Refitting the rocker-arms cover
GP 800 i.e. Maintenance