Xenon/Granit User Guide 197
Code 93
< Default All Code 93 Settings >
Code 93 On/Off
Code 93 Message Length
Scan the bar codes below to change the message length. Refer to Message Length
Description (page 188) for additional information. Minimum and Maximum
lengths = 0-80. Minimum Default = 0, Maximum Default = 80.
Code 93 Append
This function allows the scanner to append the data from several Code 93 bar
codes together before transmitting them to the host computer. When this function
is enabled, the scanner stores those Code 93 bar codes that start with a space
(excluding the start and stop symbols), and does not immediately transmit the
data. The scanner stores the data in the order in which the bar codes are read,
deleting the first space from each. The scanner transmits the appended data when
it reads a Code 93 bar code that starts with a character other than a space.
Default = Off.
* On
Off
Minimum Message Length
Maximum Message Length
On