Xenon/Granit User Guide 209
UPC-A/EAN-13 with Extended Coupon Code
Use the following codes to enable or disable UPC-A and EAN-13 with Extended
Coupon Code. When left on the default setting (Off), the scanner treats Coupon
Codes and Extended Coupon Codes as single bar codes.
If you scan the Allow Concatenation code, when the scanner sees the coupon
code and the extended coupon code in a single scan, it transmits both as one sym-
bologies. Otherwise, it transmits the first coupon code it reads.
If you scan the Require Concatenation code, the scanner must see and read the
coupon code and extended coupon code in a single read to transmit the data. No
data is output unless both codes are read. Default = Off.
Addenda Timeout
You can set a time during which the scanner looks for an addenda. If an addenda is
not found within this time period, the data can be either transmitted or discarded,
based on the setting you are using for UPC-A/EAN-13 with Extended Coupon
Code. Set the length (in milliseconds) for this timeout by scanning the bar code
below, then setting the timeout (from 0-120 milliseconds) by scanning digits from
the Programming Chart, beginning on page 353 of this manual, then Save. Default
= 500.
Note: The Addenda Timeout setting is applied to all addenda and coupon code searches.
* Off
Allow Concatenation
Require Concatenation
Addenda Timeout