Page #45 background imageLoading...
Page #45 background image
Xenon/Granit User Guide 25
Wincor Nixdorf RS232 Mode A
Scan the following Plug and Play code to program the scanner for a Wincor Nixdorf
RS232 Mode A terminal. This bar code sets the baud rate to 9600 bps and the data
format to 8 data bits, odd parity, 1 stop bit. The following prefixes are programmed
for each symbology:
Note: This setting is not supported in Granit devices.
Pair with a Honeywell Vehicle Mount Computer
A Xenon/Granit scanner can pair with Honeywell vehicle mount computers, such
as the Thor VM1 or VM2, or with Tecton mobile computers.
Scan the EZPairing bar code that is either supplied with the vehicle mount com-
puter, attached to the vehicle mount computer, or displayed on the screen. The
EZPairing bar code begins with {FNC3} LnkB, followed by 12 digits, like the sample
below.
Keyboard Country Layout
If your interface is USB Keyboard or Keyboard Wedge, your keyboard layout default
is a US keyboard. To change this layout, scan the appropriate Keyboard Country
bar code below. By default, national character replacements are used for the fol-
Wincor Nixdorf Beetle Settings
Symbology Prefix Symbology Prefix
Code 128 K EAN-13 A
Code 93 L GS1-128 K
Codabar N Interleaved 2 of 5 I
UPC-A A0 Plessey O
UPC-E C Straight 2 of 5 IATA H
EAN-8 B GS1 DataBar E
All other bar codes M
Wincor Nixdorf RS232 Mode A
Settings

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Xenon Series and is the answer not in the manual?

Honeywell Xenon Series Specifications

General IconGeneral
BrandHoneywell
ModelXenon Series
CategoryScanner
LanguageEnglish

Related product manuals