EasyManuals Logo
Home>Honeywell>Scanner>Xenon Series

Honeywell Xenon Series User Manual

Honeywell Xenon Series
376 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #97 background imageLoading...
Page #97 background image
Xenon/Granit User Guide 77
fere with other users of the ISM band, the number of attempts to connect is limited
by this setting. After the maximum number of attempts is reached, the scanner will
not attempt to reconnect to a base or an Access Point. Pressing the trigger, scan-
ning an Access Point linking bar code, or placing the scanner in the cradle resets
the attempt count and the scanner will again try to link.
Scan the Maximum Link Attempts bar code, then scan the number of attempts for
the setting (from 0-100) from theProgramming Chart, beginning on page 353,
then Save. Default = 0.
Note: When Auto Reconnect Mode is On, setting Maximum Link Attempts to zero will cause
the scanner to try to link until the Power Time-Out Timer setting expires. When Auto
Reconnect Mode is Off, setting Maximum Link Attempts to zero will cause the
scanner to only attempt linking one time after a trigger pull.
Relink Time-Out
Relink Time-Out controls the idle time between relink attempts. An attempt to link
a scanner to a base or an Access Point typically lasts up to 5 seconds. This is the
time when the scanner is actually attempting a contact . Relink Time-Out controls
the amount of time, in seconds, that elapses between the end of one connection
attempt and the start of the next.
Note: The length of time for an attempt depends on the number of scanners connected to
a base unit or Access Point. An extra 7 seconds may be required when a connection is
successful.
Scan the Relink Time-Out bar code, then scan the number of seconds for the set-
ting (from 1-100) from the Programming Chart, beginning on page 353, then
Save. Default = 3 seconds.
Bluetooth/ISM Network Activity Examples
Default values
When the scanner goes out of range, the scanner repeatedly attempts to connect
to the base unit or Access Point. Each attempt consists of approximately 5 seconds
of active time followed by 3 seconds of idle time. After one hour, the scanner pow-
ers off and batch mode data is lost.
Example: Maximum Link Attempts set to 15
Other values at default setting
Maximum Link Attempts
Relink Time-Out

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Xenon Series and is the answer not in the manual?

Honeywell Xenon Series Specifications

General IconGeneral
BrandHoneywell
ModelXenon Series
CategoryScanner
LanguageEnglish

Related product manuals